Ver detalles1. Design, supply, and installation of the electrical system for the outdoor kitchen.
2. Full compliance with nec (nfpa 70) and florida building code (fbc).
3. Dedicated circuit for outdoor refrigerator (20 a, 120 v, gfci).
4. Circuit for countertop receptacles (20 a, 120 v, gfci, spaced every 24 inches per nec 210.52).
5. Circuit for additional electrical accessories (e.g., garbage disposal, water pump, exhaust fan, etc.).
6. All exposed receptacles shall be wr (weather resistant) type with in-use covers.
7. Mandatory gfci protection for all receptacles located within 6 ft of the sink or on countertops.
8. Conduit shall be pvc schedule 40/80 or galvanized emt, depending on exposure conditions.
9. All connections shall be sealed in nema 3r or nema 4x enclosures rated for outdoor use.
10. Grounding system shall be bonded to the main service grounding electrode system of the residence.